PC1600A Series (20/30/40A)

MPPT Solar Charge Controller

MPPT (Maximum Power Point Tracking)Solar Charge Controller offer an efficient, safe, multi-stage recharging process that prolongs battery life and assures peak performance from a solar array. Each Charge Controller allows customized battery recharging.

Category: Tag: Product ID: 25995

Description

■ LCD display , easy to operate on LCD screen
■ Multi stage charging (3-stage charging , parallel charging and equalized charging function)
■ BTS – Battery remote temperature sensor terminal
■ Enable to charge Li-thium, Gel , lead-acid battery
■ With RS485 & USB communication port
■ Protection: PV array short circuit, PV reverse polarity, Battery reverse polarity, Over charging, Output short circuit

MODEL PC16-2015A PC16-3015A PC16-4015A
Nominal Battery System Voltage 12VDC / 24VDC (Auto Detection)
CONTROLLER INPUT
PV Open Circuit Voltage 12V 100VDC
24V 145VDC
PV Array MPPT Voltage Range 12V 16VDC~100VDC
24V 32VDC~130VDC
Max
PV Input Power
12V 300W 450W 600W
24V 600W 900W 1200W
BATTERY
Absorption Voltage 12V 12.5VDC
24V 25.0VDC
Refloat Voltage 12V 13.7VDC
24V 27.4VDC
Float Voltage 12V 14.3VDC
24V 28.6VDC
Low Voltage Protection Point 12V 10.0VDC
24V 20.0VDC
DC OUTPUT
Output Voltage 12V 10.0~14.5VDC
24V 20.0~29.0VDC
Peak Conversion Efficiency 98%(MPPT Efficiency 99%)
Max Charging Current 20 amps continuous 30 amps continuous 40 amps continuous
Max Output Current 20 amps continuous 20 amps continuous 20 amps continuous
Low Voltage alarm 12V 10.25VDC
24V 20.5VDC
Low Voltage
cut off
12V 10.0VDC
24V 20.0 VDC
Low Voltage Recovery 12V 11.0VDC
24V 22.0VDC
DISPLAY & PROTECTION
LED Indication Systematic operation, LV indication, LV protection, Over charge protection Loads protection, Short circuit protection
LED Display Charge Voltage, Charge Current, Voltage of storage battery, Capacity of storage battery, Output current
Alarm Protections PV array short circuit, PV reverse polarity
Battery reverse polarity, Over charging protrction
Output short circuit protection
Low voltage protection for storage battery
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Machine Dimension (W*H*D)(mm) 154*236*88
Package Dimension (W*H*D)(mm) / / /
N.W(kg) /
G.W(kg) / / /
OTHER
Environmental Rating Indoor
Radiating Mode Automatic cooling
Operating Temperature Range 0°C~ 55°C
Loading (20GP/40GP/40HQ) 2500pcs / 5000pcs / 5800pcs
CERTIFICATION & STANDARDS
UKCA (BS IEC62109-1:2010)+CE-LVD(EN IEC62109-1:2010)
CE-EMC+LVD (EN6100-6-3:2007+A1:2011,EN6100-6-1:2019+EN IEC62109-1:2010)