PV3900 TLV Series (AC:110/220V 8-12KW)

Low Frequency Solar Inverter PV 250V | MPPT 200A |DC 48V

PV3900 TLV series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger to offer uninterruptible power support. The comprehensive LCD display offers userconfigurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.

Description

■ Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
■ Built-in MPPT solar charge controller 200A
■ MPPT efficiency max 98%
■ Powerful charge rate up to 200A
■ Inside BMS function
■ DC start &Automatic Self-Diagnostic Function
■ WIFI monitoring function (optional)
■ Compatible to generator
■ Parallel operation with up to 3 units

MODEL PV39-8048 TLV PV39-10048 TLV PV39-12048 TLV
Nominal Battery System Voltage 48VDC
Stand-alone mode Yes
Parallel operation 3 units
INVERTER OUTPUT
Rated power 8KW 10KW 12KW
Surge rating 24000VA 30000VA 36000VA
Capable of starting electric motor 4HP 5HP 6HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal output voltage RMS 100V/110V/120V/200V/220V/240V
Inverter effciency(peak) >90%
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 10ms(max)
AC INPUT
Voltage 220V/230V/240V
Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
BATTERY
Low battery voltage cutoff 40-48VDC for 48VDC mode
Low battery voltage recover 42-50VDC for 48VDC mode
High battery voltage cutoff 60VDC for 48VDC mode
High battery voltage recover 57VDC for 48VDC mode
No-load loss <50W
AC CHARGER
Output voltage Depends on battery type (Supports lead-acid, gel, and lithium batteries)
Charger AC input breaker rating 100A
Overcharge protection S.D. 62.8VDC for 48VDC mode
Maximum charge current 10-140A (setting) battery terminal
BTS
Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Software + Circuit breaker
Output short circuit protection Software + Circuit breaker
Bypass breaker rating 63A
Max bypass current 80A
SOLAR CHARGER
Maximum PV charge current 200A
DC voltage 48V
Maximim PV array power 10000W 10000W 10000W
MPPT range @ operating voltage(VDC) 64~235VDC
Maximum PV array open circuit voltage 250VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Packing Wooden box
Machine Dimension (W*H*D)(mm) 439*660.5*233.2
Package Dimension (W*H*D)(mm) 782*314.5*520.5
N.W(kg) 55 62 69
G.W(kg) 73 80 87
OTHER
Operation temperature range 0°C to 50°C
Storage temperature 15°C to 60°C
Audible noise 60dB MAX
Communication WiFi
Display LED+LCD
Standard Warranty 2 year
CERTIFICATION & STANDARDS
CE-LVD (IEC62109-1:2010, EN IEC62109-2:2011); UL1741