Description
Performance:
• Double conversion online design, 0ms exchange output, single input and single output voltage.
• With DSP digital control technology, Excellent performance index, the control system more stable and reliable.
• With active power factor correction technique (PFC), Input power factor close to 1, greatly reducing the pollution of the electricity grid.
• Ultra-wide input voltage range.
• Input frequency range of 40~70Hz, to ensure access to a variety of fuel generators can work.
• LCD + LED using real-time display, the user can intuitively understand the operating state of the UPS.
• Has turned self-diagnostic function, can detect hidden faults of UPS.
• With AC input over-voltage and under-voltage protection, output overload protection, short-circuit protection, temperature protection, battery under-voltage warning protection and battery overcharge protection, etc.
• Overall efficiency 94.5% reduction in power loss of UPS, saving the user’s cost.
• When there is no utility power, it can directly use the battery to start working.
• When the utility power is restored, the UPS can automatically turn on and charge the battery at the same time to realize the unattended function.
• When the electricity is interrupted, UPS will discharge untill power off during battery mode.
• The standard RS232 communication interface enables multi-functional and multi-purpose monitoring and management operations between the UPS and
computer through a computer window, and an SNMP card (optional) can be installed to realize the UPS remote monitoring function.
Specification:
Model | EH9335- 10KRS | EH9335- 15KRS | EH9335- 20KRS | EH9335- 30KRS | EH9335- 40KRS |
---|---|---|---|---|---|
RatedPower | 10KAVA/9KW | 15KVA/13.5KW | 20KVA/18KW | 30KVA/27KW | 40KVA/32KW |
Input | |||||
Input format | Three-phase four- line+ground | ||||
Rated input voltage | AC 380V/400V/415V | ||||
Voltage range | AC 208V~478V | ||||
Frequency range | 45-55Hz at50Hz/54-66Hz at60Hz (Auto sensing) | ||||
Input power factor | ≥0.99 | ||||
Input current harmonic | ≤3% (100% Nonlinear load) | ||||
Bypass range | Bypass protection voltage upper limit: 220V: +25% (Optional +10%, +15%, +25%)
230V: +20% (Optional+ 10%, +15%) 240V: +15% (Optional+10%) |
||||
Bypass protection voltage lower limit: -45% (Optional -20%-30%) | |||||
Bypass frequency protection range: ±10% | |||||
Output | |||||
Output | Three-phase four-line + ground | ||||
Output Voltage | AC 380V/400V/415V | ||||
Output power factor | 0.8/0.9 | ||||
Output range | ±1% | ||||
Output frequency | Online Mode: following utility electricity frequency, battery mode: 50/60Hz±0.2% | ||||
Load peak ratio | 3:1 | ||||
Output harmonic distortion | ≤ 2% Linear Load ≤ 5% Nonlinear Load | ||||
Battery | |||||
Battery Number | Optional: DC±192V/204V/216V/228V/240V (±16/17/18/19/20 pcs) Default: DC±192V | ||||
Charging Current | 10A max | ||||
Protection | |||||
Overload Protection | Loading ≤ 110%, 60min; ≤ 125%, 10min; ≤ 150%, 1min; ≥ 150% change to bypass | ||||
Over temperature | Normal mode: change to bypass mode; Battery mode: stop output | ||||
Emergency shutdown (EPO) | Stop output | ||||
Other | |||||
Change-over time | Utility mode to bypass mode: 0ms (tracking); utility mode to battery mode: 0ms | ||||
Normal mode (Full load) | ≥efficiency 94.5% | ||||
Communication Connection | RS232,RS485,SNMP (Optional) | ||||
ECO mode | support | ||||
Self-test function | support | ||||
Parallel function | Max 4pcs | ||||
Working environment | |||||
Working temperature | 0~40℃ | ||||
Storage Temperature | -25~55℃ (batteries: 0~40℃ ) | ||||
Relative humidity | 0%~95% (no condensation) | ||||
Altitude | < 1500m, when above 1500m, when above 1500m, derate according to GB/T 3859.2 | ||||
Physical Characteristics | |||||
Size (D*W*H) (mm) | 580*443*131 | ||||
Net Weight (kg) | 32 | 32.5 | 33 | 33.5 | 34 |