Description
■ 3-in-1: Wall-mounted, Stacked-mounted, Rack-mounted(optional)
■ Large capacity, high power output
■ Safest lithium iron phosphate battery cell with high energy density
■ Modular design: supports up to 15 units in parallel
■ Support CAN & RS485 communication with mainstream inverters
■ Local monitoring via LCD monitor
■ Built-in WiFi Smart BMS Module
Technical Data | LP16-24100 | LP16-24200 | LP16-48100 | LP16-48200 | |
Nominal Voltage | 25.6V | 51.2V | |||
Nominal Capacity | 100Ah | 200Ah | 100Ah | 200Ah | |
Nominal energy | 2560Wh | 5120Wh | 5120Wh | 10240Wh | |
Life Cycles | 6000 cycles @ 80% DOD, 25℃ | ||||
Recommended Charge Voltage | 29.2V | 58.4V | |||
Recommended Charge Current | 20A | 40A | 20A | 40A | |
End Of Discharge Voltage | 22V | 44V | |||
Standard Method | Charge | 20A | 40A | 20A | 40A |
Discharge | 50A | 100A | 50A | 100A | |
Maximum Continuous Current | Charge | 100A | 150A | 100A | 150A |
Discharge | 100A | 150A | 100A | 150A | |
BMS Cut-Off Voltage | Charge | 29.2 V (3.65V/Cell) | 58.4 V (3.65V/Cell) | ||
Discharge | 22.0V (2s) (2.75V/Cell) | 44.0V (2.75V/Cell) | |||
Temperature | Charge | 0 ~ 45℃ | |||
Discharge | -10 ~ 55 ℃ | ||||
Storage Temperature | 15~35℃ | ||||
Shipment voltage | ≥25.6V | ≥51.2V | |||
Module Parallel | Up to 15 units | ||||
Communication | CAN2.0/RS232/RS485 | ||||
IP Protection level | IP21 | ||||
Case Material | SPCC | ||||
Machine Dimension (H*W*D) (mm) | 485.5*442*177 | 486.5*442*250 | 625.5*442*177 | 686.5*442*250 | |
Package Dimension (W*H*D) (mm) | carton box | 557*547*227 | 557*547*300 | 688*557*227 | / |
wooden box | 555*565*340 | 555*565*410 | 696*565*335 | 759*569*391 | |
N.W (kg) | 27 | 44 | 45 | 80 | |
G.W (kg) | carton box | 30 | 48 | 48 | / |
wooden box | 40 | 57 | 58 | 97 | |
* Variations in dimensions and weights may occur due to production batches. | |||||
Charge Retention And Capacity Recovery Capability | Standard charge the battery, and then put aside at room temperature for 28d or 55 ℃ for 7d, Charge retention rate≥90%, Recovery rate of charge≥90% | ||||
Certification & Standards | CE-EMC (EN 61000-6-3: 2007+A1: 2011+AC: 2012 EN IEC 61000-6-1: 2019) IEC62619-1:2018; IEC62619:2022; IEC62619:2017; UN38.3/ MSDS |