Description
■ 100% unbalanced output, each phase max. output up to 50% rated power
■ Max. 6 pcs parallel for on-grid and off-grid operation
■ AC couple to retrofifit existing solar system
■ Support multiple batteries parallel
■ Max. charging/discharging current of 220A
■ Support storing energy from diesel generator
■ 48V low voltage battery, transformer isolation design
■ IP66 water-proof and dust-proof
■ “Time of use” function: a maximum of 6 time segments can be set
■ Wifi monitoring
MODEL | PH11-5KL2-US | PH11-6KL2-US | PH11-8KL2-US | PH11-10KL2-US |
Rated power | 5000W | 6000W | 8000W | 10000W |
BATTERY INPUT DATA | ||||
Battery type | Lead-acid battery / Lithium battery | |||
Battery voltage | 48V | |||
Battery voltage range | 40~64V | |||
Charging curve | 3-stage adaptive with maintenance/Equalization | |||
Charging Strategy for Li-lon Battery | Self-adaption to BMS | |||
Over-current protection/ Over-temperature protection | Yes / Yes | |||
Maximum charging/discharging power | 5000W | 6000W | 8000W | 10000W |
Maximum charging/discharging current | 110A | 130A | 170A | 220A |
PV STRING INPUT DATA | ||||
Max. DC Input Power | 6500W | 7800W | 10400W | 13000W |
Maximum DC voltage | 600V | |||
Start-up Voltage | 125V | |||
Full Load DC Voltage Range | 150~500V | |||
Rated PV Input Voltage | 370V | |||
Minimum voltage for grid connection | 150V | |||
Enter high voltage error recovery point | 600V | |||
Maximum input current | 16A/16A | 16A/16A | 32A/16A | 32A/16A |
No.of MPP Trackers | 2 | 2 | 2 | 2 |
Input terminal type | H4/MC4 | |||
AC INPUT/OUTPUT DATA | ||||
Rated AC Input/ Output Power | 5000W | 6000W | 8000W | 10000W |
Max AC Input/ Output Power | 5000W | 6000W | 8000W | 10000W |
AC Input/ Output Rated Current | 20.8A/19.2A | 25A/23A | 33.3A/30.7A | 41.6A/38.4A |
Rated Input/Output Voltage/Range | 120V/240V:208V | |||
Rated Input/Output Grid Frequency/Range | 60Hz±5Hz/ 50Hz±5Hz | |||
Rated output power factor | 1 | |||
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||
Total Harmonics Current Distortion (THDi) | <3% | |||
Grid Type | Split Phase | |||
DC Current Injection | <0.5% | |||
EFFICIENCY | ||||
Max. Efficiency | 97.5% | |||
Euro Efficiency | 96.5% | |||
MPPT Efficiency | 99.5% | |||
PROTECTION | ||||
Integrated | Islanding protection, Output overcurrent protection, Output overvoltage protection, PV input polarity reverse protection, DC Switch (optional), Ground Fault Sensing, leakage current monitoringprotection | |||
Surge Protection | DC Type III/AC Type III | |||
Overvoltage Category | DC Type II/AC Type III | |||
GENERAL DATA | ||||
Operating Temperature Range (°C) | -25°C~+60°C, >45°C Derating | |||
Cooling | Fan cooling | |||
Noise (dB) | ≤50dB | |||
Altitude | 3000m, >3000mDerating | |||
Topology | Battery-side transformer isolation, PV-side non-transformer isolation | |||
Communication | USB/ WiFi/ Enternet(optional) | |||
Display | 4.3-inch touch screen | |||
Protection Degree | IP66 | |||
Installation Style | Wall-mounted | |||
MECHANICAL SPECIFICATIONS | ||||
Machine Dimension (W*H*D)(mm) | 446*692*260 (excluding connectors and racks) | |||
Package Dimension (W*H*D)(mm) | 816*404*567 | |||
N.W(kg) | 38 | |||
G.W(kg) | 42 | |||
Warranty | 5 Year the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
|||
CERTIFICATION & STANDARDS | ||||
NBT32004-2013 |