Skip to content Skip to footer

PV3000 VPM Series (1-3KVA)

Low Frequency Off Grid Solar Inverter 1~3KVA | AC 120/230V | MPPT 60A | DC 12V,24V | PV 75V/100V | BAT-CAN

PV3000 VPM series is very economical pure sine wave solar inverter, inbuilt with 60A MPPT Charger and AC Charger from 20A to 60A; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower, in this way system charge is optimazed best. It enables inverter to operate with all kinds of home appliances.

Category: Tag: Product ID: 26106

Description

■ 3 Steps charging
■ Overload and short-circuit protection
■ Set charging voltage/charging current
■ Battery low voltage shutdown point can be set to 10/10.5/11/11.5/12V
■ Power-save mode
■ Set utility priority/battery priority
■ Set utility input wide/narrow range
■ Inverter voltage can be set to 110V/115V/120V or 220V/230V/240V
■ Inverter frequency can be set to 50Hz/60Hz
■ Set utility charging on/off switch
■ Inbuilt with 60A MPPT Solar Charge Controller
■ Acid or Lithium Select
■ WIFI remote monitoring (optional)
■ With BMS lithium battery communication function (CAN port)

MODEL PV30-1K VPM PV30-1.5K VPM PV30-2K VPM PV30-3K VPM
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC
INVERTER OUTPUT
Rated Power 1000VA 1500VA 2000VA 3000VA
Surge Rating 3000VA 4500VA 6000VA 9000VA
Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS 110V /115V / 120V / 220V / 230V / 240VAC (±10% RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 0.7
Typical Transfer Time 10ms(max)
Overload 100% < Load < 110% (alarm 5min then stop output and fault code 07) 110% < Load < 125% (alarm 60s then stop output and fault code 07) Load > 125% (alarm 10s then stop output and fault code 07)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 75~135VAC; 155~265VAC (For personal computers)
Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Voltage Alarm (10V/ 10.5V/ 11V/ 11.5V/ 12V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Voltage Cut Off 10V/ 10.5V/ 11V/ 11.5V/ 12V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Alarm (12~14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (12~14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Energy Saving Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
Output Voltage Depends on battery type
Charge AC Input Breaker Rating 120V 1~2K/30A 3K/40A
230V 1~3K/30A
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode)
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A
BYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
AC Input Breaker 1-3K/30A
SOLAR CHARGER
Maximum PV Array Power 1000W 2000W 1000W 2000W 1000W 2000W 2000W
Maximum PV Charge Current 60A
DC Voltage 12V / 24V auto work
MPPT Range @ Operating Voltage 12V: 16~75VDC; 24V: 32-100VDC
Maximum PV Array Open Circuit Voltage 12V:75VDC; 24V:100VDC
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Dimensions (W*H*D) (mm) 303*493*200
Package Dimensions (W*H*D) (mm) 615*400*319
N.W (kg) /
G.W (kg) /
OTHER
Operating Temperature Range 0°C to 40°C
Storage Temperature -15°C to 60°C
Audible Noise 60dB MAX
Display LED+LCD
Standard Warranty 2 year

Request a Quote

    Headquarters
    Address: Building 8, South China power innovation Science Park, No.115 zhangcha 1st road, Foshan, China
    Get In Touch

    +86 755 83657660 (Europe)
    +86 755 83651325/+86 757 82629306 (Americas)
    WhatsApp

    MUST ENERGY © 2024. All Rights Reserved.